OVERVIEW

WHAT WE DO

Demand charges — the portion of your utility bill based on peak consumption in a 15-minute interval — are often the largest and least-understood component of a commercial facility's energy cost. A single monthly peak determines the demand charge for the entire billing period. Lightning Mobile Electric installs monitoring, control, and automation systems that give facility managers the data and the tools to reduce that peak — and the recurring monthly cost that follows it. We serve industrial, commercial, and retail facilities across the Intermountain West.

CAPABILITIES

SCOPE OF SERVICE

POWER MONITORING & SUB-METERING

Revenue-grade power meters and current transformers installed at the service entrance, feeder level, or individual equipment circuits give facility managers accurate consumption data organized by department, process, or system. Sub-metering enables cost allocation across tenants or cost centers, identifies energy waste by circuit, and provides the baseline data required to measure the actual savings from efficiency improvements.

  • • Revenue-grade service entrance metering
  • • Sub-metering by floor, department, or tenant
  • • Equipment-level current transformer installation
  • • Real-time energy dashboard configuration
  • • Historical data logging and trending
  • • Interval data export for utility rebate documentation

DEMAND CONTROL & LOAD SHEDDING

Automated demand control systems monitor consumption in real time and shed non-critical loads before the demand interval peak is set. HVAC systems, hot water heaters, non-critical lighting, and industrial loads are candidates for automated demand response. We program load priority sequences that protect production and comfort loads while shedding lower-priority consumption to stay below a target demand threshold.

  • • Real-time demand monitoring with threshold alerting
  • • Automated load shedding and sequencing
  • • HVAC pre-cooling and demand reset strategies
  • • Lighting load control for demand reduction
  • • Demand response program enrollment coordination
  • • Demand charge savings calculation and verification

BMS & EMS INTEGRATION

Electrical monitoring and control systems are most effective when integrated with the facility's building management system (BMS) or energy management system (EMS). We wire and configure BACnet, Modbus, and proprietary protocol integrations between electrical monitoring equipment, HVAC controllers, lighting systems, and centralized facility management software — providing a single view of facility performance.

  • • BACnet and Modbus protocol integration
  • • HVAC demand reset and setpoint adjustment
  • • Lighting controls integration for occupancy-based management
  • • Fault detection and diagnostic (FDD) data feeds
  • • Utility interval data integration with BMS
  • • Centralized facility management software connection

POWER FACTOR CORRECTION

Facilities with significant motor loads, variable frequency drives, or electronic equipment often carry a power factor below the utility's target — typically 0.95. Low power factor triggers a utility power factor surcharge and increases current on conductors and transformers. We install automatic power factor correction capacitor banks that maintain power factor above the utility's threshold — eliminating surcharges and reducing conductor heating.

  • • Power factor baseline measurement and analysis
  • • Automatic capacitor bank sizing and specification
  • • Harmonic filter specification where drives are present
  • • Capacitor bank installation and commissioning
  • • Power factor verification measurement after installation
  • • Utility surcharge elimination documentation

TECHNICAL SPECIFICATIONS

THE SPEC SHEET BEHIND AN ENERGY PROJECT

Energy management is metering, control strategy, and power quality. Without all three, a building gets dashboards it never acts on.

METERING & VISIBILITY

SUBMETERING
Tenant, floor, or system-level kWh, kW, and demand
CURRENT TRANSFORMERS
Split-core or solid, sized to conductor and range
COMMUNICATION
Modbus, BACnet, or pulse output to the owner's platform
DATA RETENTION
Interval data logged at 15-minute resolution or better
BILLING RECONCILIATION
Metered data reconciled against the utility invoice

CONTROL STRATEGIES

SCHEDULING
Occupancy-based rather than fixed-clock wherever possible
DEMAND RESPONSE
Load shed and curtailment sequences with verified override
SETPOINT & STAGING
HVAC, pumping, and lighting staged to actual demand
POWER FACTOR
Capacitor banks or detuned filters where PF penalties apply
HARMONIC MITIGATION
Filtering where drive and rectifier loads distort the service
FAILSAFE
Manual override and safe default on every automated sequence

MEASUREMENT & VERIFICATION

BASELINE
Weather- and occupancy-normalized pre-project model
SAVINGS
Measured against baseline, not against nameplate estimates
ROI
Documented payback against actual utility rate structure
REBATES
Utility incentive documentation prepared and submitted
REPORTING
Monthly trend reports the owner can actually read

TRUSTED BY FORTUNE 500 AND NATIONAL ACCOUNTS

Walmart
Boeing
Matbro
Caterpillar
United Industries
Key Energy
MSI
Pollard Banknote
BOK
Lululemon
FedEx
Hobby Lobby
Target
Ulta Beauty
Sephora
Chase Bank
Wells Fargo
Amazon
Walmart
Boeing
Matbro
Caterpillar
United Industries
Key Energy
MSI
Pollard Banknote
BOK
Lululemon
FedEx
Hobby Lobby
Target
Ulta Beauty
Sephora
Chase Bank
Wells Fargo
Amazon

DIAGNOSTIC METHOD

HOW WE FIND THE WASTE

Before anything is controlled, it is measured. These are the four instruments that tell a building where its money is going.

01POWER QUALITY ANALYZER

PROFILE THE SERVICE

A week or more of logging at the service entrance and major panels: demand peaks, load factor, power factor, and harmonics — the shape of how the building actually consumes.

02HARMONIC ANALYSIS

FIND THE DISTORTION

Drive and rectifier loads reviewed for harmonic content and neutral heating. Filtering or derating decisions come from measurement, never from a rule of thumb.

03SUBMETER COMPARISON

ISOLATE THE CULPRIT

System-level submetering compared side by side to find the circuit that runs all night. Most savings hide in one schedule nobody ever changed.

04VERIFICATION METERING

PROVE THE PAYBACK

Post-implementation metering on the same intervals as the baseline, reconciled to the utility bill so the savings are real money, not a model.

THE 3P METHOD

HOW WE DELIVER

01

AUDIT

Utility bill analysis, demand charge review, power factor assessment, and baseline consumption measurement — identifying where the largest cost reduction opportunities exist.

02

DESIGN

Monitoring system specification, demand control strategy, load priority sequencing, and BMS integration architecture — designed to the facility's specific load profile.

03

INSTALL

Meter and CT installation, demand control wiring, BMS integration, capacitor bank installation, and network configuration — coordinated to minimize operational disruption.

04

OPTIMIZE

System commissioning, demand threshold programming, load priority validation, performance measurement against the pre-installation baseline, and ongoing reporting setup.

WHY US

MEASURED SAVINGS, NOT ESTIMATES

We have spent 38 years inside commercial and industrial buildings watching how power actually gets used — plants, distribution centers, data halls, retail portfolios, and hospitality properties across 12 states. That field experience is why our energy work starts with metering instead of a proposal. When we tell an owner a project pays back in a certain number of months, we have the interval data, the utility rate structure, and the verification plan to stand behind it.

38
YEARS IN BUSINESS
4
BRANCH LICENSES
$200M+
PROJECTS COMPLETED
10M+
FIXTURES MANAGED
24/7
EMERGENCY RESPONSE
12
STATES SERVED

LICENSED, REGISTERED, INSURED

COLORADO LICENSE
EC.0101552 · ME.0030199
TEXAS LICENSE
ME.576645
UTAH LICENSE
ME.123080445-5502
WYOMING LICENSE
M-52758
SAFETY PROGRAM
OSHA 10 · 30 · 1910.146
DUNS / CAGE
080513384 / 8THW9

VERTICAL FIT

INDUSTRIES WE SERVE

RETAIL & GROCERY

Multi-site retail electrical, lighting, and emergency service programs.

READ MORE

WAREHOUSE & DISTRIBUTION

High-bay lighting, power distribution, and dock electrical for logistics sites.

READ MORE

DATA CENTERS

Critical power, structured cabling, and concurrent maintenance in live white space.

READ MORE

MANUFACTURING

Industrial power, controls, and production support for plants and refineries.

READ MORE

HEALTHCARE & MEDICAL

Patient-care electrical, emergency power, and code-compliant installations.

READ MORE

HOSPITALITY & HOTEL

Guest experience lighting, EV charging, and property-wide electrical service.

READ MORE

COMMON QUESTIONS

FREQUENTLY ASKED

24/7 EMERGENCY