
SERVICE · ELECTRICAL MAINTENANCE
ELECTRICAL MAINTENANCE & SERVICE AGREEMENTS
PLANNED MAINTENANCE · INFRARED SCANS · SWITCHGEAR SERVICE · PRIORITY DISPATCH
OVERVIEW
WHAT WE DO
Most commercial electrical failures are not random. Loose terminations, overloaded circuits, degraded breakers, and dust-loaded switchgear announce themselves months before they fail — in heat, in vibration, and in the paperwork nobody reads. Lightning Mobile Electric builds planned electrical maintenance programs that find those conditions on a schedule instead of during an outage. Programs are scoped to the facility: annual switchgear service, infrared thermographic surveys, breaker and panel maintenance, standby power testing, and a documented report your insurer, AHJ, and ownership group can actually use. Clients on a service agreement also get priority dispatch, so when something does fail they are not waiting in a queue behind new work.
CAPABILITIES
SCOPE OF SERVICE
PLANNED MAINTENANCE PROGRAMS
A written maintenance program aligned to NFPA 70B recommended practice for electrical equipment maintenance — the standard insurers and ownership groups increasingly ask for by name. We inventory the service, distribution, and branch equipment, assign each item a service interval based on criticality and condition, and execute it on a recurring schedule. Every visit produces documentation: what was inspected, what was measured, what was corrected, and what is trending toward replacement.
- • Equipment inventory and criticality assessment
- • Annual, semi-annual, or quarterly service intervals
- • Torque verification on terminations and bus connections
- • Infrared scans on energized equipment under load
- • Breaker exercising and contact inspection
- • Written condition reports with photo documentation
INFRARED THERMOGRAPHIC SURVEYS
Thermal imaging finds the loose lug, the failing breaker, and the unbalanced phase before they become a service call at 2 a.m. We scan panels, switchgear, disconnects, motor control centers, and distribution boards while the facility is under normal load, then deliver a report that ranks every finding by severity with the temperature delta, the probable cause, and the corrective action. Findings that need immediate attention are corrected the same visit where the site allows it.
- • Switchgear, panel, and MCC thermal scanning
- • Severity-ranked exception report with thermal images
- • Phase imbalance and load readings at each panel
- • Same-visit correction of critical findings
- • Documentation formatted for insurance and risk review
- • Re-scan after corrective work to verify the repair
SWITCHGEAR, BREAKER & PANEL SERVICE
Switchgear is the one piece of electrical equipment a facility cannot afford to lose, and the one most often neglected because it is bolted shut in a room nobody enters. Our maintenance scope covers cleaning, inspection, lubrication, contact and mechanism service, and testing on main switchgear, distribution panels, motor control centers, and molded-case and low-voltage power breakers — performed on planned outages coordinated with your operations schedule.
- • Main and distribution switchgear cleaning and service
- • Molded-case and low-voltage power breaker inspection
- • Contact wear, arc chute, and mechanism evaluation
- • Bus and lug torque verification to manufacturer specification
- • Planned outage coordination around production hours
- • Replacement recommendations with lead-time planning
STANDBY POWER & LIFE-SAFETY TESTING
Emergency power that has never been tested under load is an assumption, not a backup. We maintain and test standby generators, automatic transfer switches, UPS systems, and battery strings on a schedule that satisfies code requirements and proves the system actually carries the load. Emergency and egress lighting, exit signs, and life-safety circuits are included so the annual inspection does not become a separate vendor relationship.
- • Generator exercise and load bank testing
- • Automatic transfer switch operation and service
- • UPS battery inspection, testing, and replacement
- • Emergency and egress lighting verification
- • Transfer time and runtime documentation
- • Corrective repairs scheduled from test results
PRIORITY RESPONSE SERVICE AGREEMENTS
A maintenance agreement changes what happens on the worst day. Agreement clients are dispatched ahead of non-contract calls, reach a technician who already knows the building and its equipment history, and avoid after-hours premium billing on covered service. For multi-site portfolios we hold the electrical history for every location, so a property manager can call once and get a technician who arrives already knowing which panel feeds the failed circuit.
- • Priority dispatch ahead of non-contract work
- • No after-hours premium on covered service calls
- • Equipment history and site documentation on file
- • Single point of contact for multi-site portfolios
- • Consolidated invoicing and annual reporting
- • 24/7 emergency line staffed by our own technicians
TECHNICAL SPECIFICATIONS
THE SPEC SHEET BEHIND A MAINTENANCE PROGRAM
Planned maintenance is a schedule, a checklist, and a paper trail. These are the three things an owner actually receives.
SCOPE & CADENCE
- STANDARD
- NFPA 70B maintenance practices and intervals
- INFRARED SURVEYS
- Annual scan of switchgear, panels, and disconnects under load
- TORQUE VERIFICATION
- Terminations checked to manufacturer specification
- BREAKER EXERCISE
- Operation and contact condition reviewed
- BATTERY & EMERGENCY LIGHTING
- 30-second and 90-minute tests documented
- PRIORITY DISPATCH
- Program clients reach a technician first, 24/7
EQUIPMENT COVERED
- SWITCHGEAR
- Main, tie, and distribution sections including bus inspection
- PANELS & TRANSFORMERS
- Load readings, thermal scans, and ventilation checks
- MOTOR CONTROL
- Starters, VFDs, and control circuits exercised and inspected
- GENERATOR & ATS
- Exercise, transfer, and annual load test
- ELEVATOR & LIFE SAFETY CIRCUITS
- Recall and emergency power functions re-verified
- GROUNDING & BONDING
- Continuity and connection integrity verified
REPORTING & PLANNING
- THERMAL REPORT
- Images with severity ranking and recommended action
- ASSET REGISTER
- Equipment list with age, condition, and criticality
- DEFICIENCY LOG
- Open items tracked until closed, not re-found next year
- BUDGET INPUT
- Repair and replacement costs forecast for planning
- SINGLE CONTACT
- One account manager across every site in the program
TRUSTED BY FORTUNE 500 AND NATIONAL ACCOUNTS
















DIAGNOSTIC METHOD
HOW A PROGRAM RUNS
Predictable visits, measurable findings, and a record that gets better every year.
SCAN EVERYTHING ONCE
A first-pass infrared and load survey of every panel and piece of major equipment, establishing the baseline that all future scans are compared against.
WORK THE INTERVALS
Visits scheduled to NFPA 70B practice, with the same technician continuity where possible so the person scanning knows what the equipment looked like last year.
COMPARE, DON'T JUST SCAN
Each scan compared to the prior one. A termination that is 10 degrees warmer than last year is a finding even when it is still within tolerance.
CLOSE THE LOOP
Findings ranked by severity, repairs quoted and scheduled, and the deficiency log carried forward so the same item does not appear as new every cycle.

THE 3P METHOD
HOW WE DELIVER
ASSESS
A walkthrough of the service entrance, distribution, and critical loads. We document equipment, age, condition, and existing documentation gaps, and identify what has never been serviced.
BASELINE
Thermal scan, load readings, and torque verification on the equipment that matters most — establishing the baseline that every future visit is measured against.
SCHEDULE
A written program with defined intervals, planned outage windows coordinated with operations, and a service calendar that does not depend on someone remembering to call.
REPORT
Each visit closes with documentation: findings ranked by severity, work performed, recommended repairs, and a rolling replacement plan for equipment approaching end of life.
WHY US
38 YEARS OF KNOWING WHAT FAILS
We have maintained commercial and industrial electrical systems since 1987, and we have seen what fails first: terminations, breakers that never get exercised, batteries nobody tests, and emergency circuits that were assumed to work. Our maintenance programs exist to turn that experience into a schedule — across plants, distribution centers, data halls, and multi-site retail portfolios in 12 states, with a single account contact and a documented record for every visit.
LICENSED, REGISTERED, INSURED
- COLORADO LICENSE
- EC.0101552 · ME.0030199
- TEXAS LICENSE
- ME.576645
- UTAH LICENSE
- ME.123080445-5502
- WYOMING LICENSE
- M-52758
- SAFETY PROGRAM
- OSHA 10 · 30 · 1910.146
- DUNS / CAGE
- 080513384 / 8THW9
VERTICAL FIT
INDUSTRIES WE SERVE
WAREHOUSE & DISTRIBUTION
High-bay lighting, power distribution, and dock electrical for logistics sites.
READ MOREDATA CENTERS
Critical power, structured cabling, and concurrent maintenance in live white space.
READ MOREHEALTHCARE & MEDICAL
Patient-care electrical, emergency power, and code-compliant installations.
READ MOREHOSPITALITY & HOTEL
Guest experience lighting, EV charging, and property-wide electrical service.
READ MORE
COMMON QUESTIONS
FREQUENTLY ASKED
AREA OF OPERATIONS
COVERING THE INTERMOUNTAIN WEST
COLORADO · UTAH · WYOMING · IDAHO · OKLAHOMA
Oklahoma
ALSO SERVING
Texas: Houston, Dallas / Fort Worth, San Antonio, Austin, El Paso, Lubbock/Montana: Billings, Bozeman, Missoula, Great Falls/Nebraska: Omaha, Lincoln, Scottsbluff, North Platte/Arizona: Phoenix, Tucson, Mesa, Flagstaff/New Mexico: Albuquerque, Santa Fe, Las Cruces, Rio Rancho/Missouri: Kansas City, St. Louis, Springfield, Columbia/Arkansas: Little Rock, Fayetteville, Fort Smith, Jonesboro